Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add filters








Year range
1.
Braz. j. phys. ther. (Impr.) ; 13(1): 1-9, jan.-fev. 2009. ilus, tab
Article in English | LILACS | ID: lil-508843

ABSTRACT

OBJECTIVE: The purpose of this manuscript is to review current knowledge of how muscle activation and force production contribute to shoulder kinematics in healthy subjects and persons with shoulder impingement. RESULTS: The middle and lower serratus anterior muscles produce scapular upward rotation, posterior tilting, and external rotation. Upper trapezius produces clavicular elevation and retraction. The middle trapezius is primarily a medial stabilizer of the scapula. The lower trapezius assists in medial stabilization and upward rotation of the scapula. The pectoralis minor is aligned to resist normal rotations of the scapula during arm elevation. The rotator cuff is critical to stabilization and prevention of excess superior translation of the humeral head, as well as production of glenohumeral external rotation during arm elevation. Alterations in activation amplitude or timing have been identified across various investigations of subjects with shoulder impingement as compared to healthy controls. These include decreased activation of the middle or lower serratus anterior and rotator cuff, delayed activation of middle and lower trapezius, and increased activation of the upper trapezius and middle deltoid in impingement subjects. In addition, subjects with a short resting length of the pectoralis minor exhibit altered scapular kinematic patterns similar to those found in persons with shoulder impingement. CONCLUSION: These normal muscle functional capabilities and alterations in patient populations should be considered when planning exercise approaches for the rehabilitation of these patients.


OBJETIVO: O objetivo deste manuscrito é revisar o conhecimento atual sobre como a ativação muscular e a produção de força contribuem para a cinemática do ombro em indivíduos saudáveis e em pessoas com síndrome do impacto. RESULTADOS: As porções média e inferior do músculo serrátil anterior produzem rotação para cima, inclinação posterior e rotação externa na escápula. O trapézio superior produz elevação e retração da clavícula. O trapézio médio é principalmente um estabilizador medial da escápula. O trapézio inferior auxilia na estabilização medial e rotação para cima da escápula. O músculo peitoral menor está alinhado para resistir às rotações normais da escápula durante a elevação do braço. O manguito rotador é crucial para a estabilização e prevenção do excesso de translação superior da cabeça do úmero, assim como para a produção de rotação externa na glenoumeral durante a elevação do braço. Foram identificadas alterações na amplitude ou no tempo de ativação em diversas investigações que compararam sujeitos portadores de síndrome do impacto com controles saudáveis. As alterações incluem ativação reduzida do músculo serrátil anterior médio ou inferior e do manguito rotador, ativação retardada do trapézio médio e inferior, assim como maior ativação do trapézio superior e do deltóide médio em sujeitos com síndrome do impacto. Além disso, sujeitos com o músculo peitoral menor com curto comprimento de repouso apresentam padrões alterados de cinemática escapular semelhantes aos encontrados em pessoas com síndrome do impacto. CONCLUSÃO: Estas capacidades musculares funcionais normais e alterações nas populações de pacientes devem ser consideradas no planejamento de programas de exercícios para a reabilitação destes pacientes.

2.
Braz. j. phys. ther. (Impr.) ; 12(3): 176-182, maio-jun. 2008. ilus, tab
Article in English, Portuguese | LILACS | ID: lil-488916

ABSTRACT

OBJETIVO: Avaliar a amplitude de movimento (ADM) e o torque flexor e extensor do joelho após a realização de um programa de alongamento ativo excêntrico dos músculos flexores do joelho. MATERIAIS E MÉTODOS: Trinta e quatro voluntários (23 mulheres e 11 homens), 34,42±9,3 anos, realizaram um programa de alongamento ativo excêntrico dos músculos flexores do joelho na postura em pé, que consistiu de sete repetições de um minuto com 30 segundos de descanso entre as repetições. O programa de alongamento foi realizado duas vezes por semana, durante quatro semanas. A ADM de extensão e o torque flexor e extensor do joelho foram avaliados no dinamômetro isocinético pré e pós-programa de alongamento. O torque foi avaliado nos modos isométrico e isocinético concêntrico e excêntrico a 30º/s e 60º/s. RESULTADOS: Houve aumento na ADM de 53,7±13º para 30,1±16º (p=0,0001), no torque isométrico flexor de 89±32Nm para 93±33Nm (p=0,01) e extensor de 178±67Nm para 187±73Nm (p=0,006). O torque flexor concêntrico e excêntrico a 30º/s aumentou de 90±31Nm para 96±31Nm (p=0,001) e de 100±34Nm para 105±35Nm (p=0,01), respectivamente. O torque extensor concêntrico a 60º/s aumentou de 144±51Nm para 151±58Nm (p=0,02) e o excêntrico a 30º/s de 175±71Nm para 189±73Nm (p=0,01). CONCLUSÕES: O programa de alongamento proposto foi efetivo para aumentar a flexibilidade dos músculos alongados e torque dos grupos musculares agonistas (alongados) e seus antagonistas.


OBJECTIVE: To evaluate the changes in knee range of motion (ROM) and torque of knee flexor and extensor muscles after an active eccentric stretching program for the knee flexor muscles. METHODS: Thirty-four volunteers (23 women and 11 men), aged 34.42±9.3 years, performed an active eccentric stretching program for the knee flexor muscles in the standing posture, consisting of seven repetitions of one minute each, with 30 seconds of resting between them. The stretching program was performed twice a week, for four weeks. Knee extension ROM and the torque of the knee flexor and extensor muscles were evaluated using an isokinetic dynamometer before and after the stretching program. The torque was evaluated in the isometric, isokinetic concentric and eccentric modes at 30º/s and 60º/s. RESULTS: There was an increase in ROM from 53.7±13º to 30.1±16º (p=0.0001), in isometric torque of the flexors from 89±32Nm to 93±33Nm (p=0.01) and of the extensors from 178±67Nm to 187±73Nm (p=0.006). The concentric and eccentric torque of the flexors at 30º/s increased from 90±31Nm to 96±31Nm (p=0.001) and from 100±34Nm to 105±35Nm (p=0.01), respectively. The concentric torque of the extensors at 60º/s increased from 144±51Nm to 151±58Nm (p=0.02), and the eccentric torque at 30º/s increased from 175±71Nm to 189±73Nm (p=0.01). CONCLUSIONS: The stretching program proposed was effective for increasing the flexibility of the stretched muscles and the torque of the agonist (stretched) muscle groups and their antagonists.


Subject(s)
Humans , Male , Female , Bone Lengthening , Knee , Physical Therapy Modalities , Pliability , Torque
3.
Braz. j. phys. ther. (Impr.) ; 11(2): 161-167, mar.-abr. 2007. tab
Article in English | LILACS | ID: lil-458022

ABSTRACT

OBJECTIVE: This study assessed physical function and pain in male and female workers with shoulder impingement syndrome using the Brazilian Portuguese versions of the Disabilities of the Arm, Shoulder and Hand (DASH) and McGill pain questionnaires. METHODS: Twenty-seven assembly line workers (18 men and 9 women; mean age of 33.26 ± 6.49 years) in the school supply industry were evaluated. The duration of the shoulder impingement pain was 31.74 ± 32.92 months and the amount of time of the workers in this industry was 11.08 ± 6.41 years. The DASH questionnaire was used to evaluate functional status and symptoms of the upper limbs of the workers. Using the McGill Pain Questionnaire, the pain was quantified by the number of words chosen and by the pain rating index (PRI). RESULTS: The women presented higher scores (P< 0.05) than the men for both DASH overall and DASH work scores. The women chose more words (17.00 ± 2.59) than the men (13.33 ± 3.16) and also presented the highest total PRI (P< 0.05). CONCLUSIONS: The results obtained in this group of Brazilian workers with shoulder impingement identify the most commonly used descriptors of shoulder pain. Further, this study shows that females are more likely than males to refer physical disability and pain. Also, the DASH and McGill pain questionnaires are important and helpful tools in the clinical evaluation of shoulder impingement syndrome.


OBJETIVO: Este estudo avaliou função física e dor em trabalhadores com síndrome do impacto através das versões brasileiras dos questionários "Disabilities of the Arm, Shoulder and Hand" (DASH) e McGill de dor. MÉTODO: Vinte e sete trabalhadores (18 homens e 9 mulheres; idade média de 33,26 ± 6,49 anos) de uma linha de produção de uma indústria de material escolar foram avaliados. O tempo de duração de dor no ombro era de 31,74 ± 32,92 meses e o tempo de trabalho na indústria era de 11,08 ± 6,41 anos. O questionário DASH foi utilizado para avaliar o estado funcional e os sintomas dos membros superiores dos trabalhadores. Através do questionário McGill de dor, a dor foi quantificada pelo número de palavras escolhidas e pelo índice de classificação da dor (ICD). RESULTADOS: As mulheres apresentaram maiores escores (P< 0,05) que os homens para ambos os módulos do DASH. As mulheres escolheram mais palavras (17,00 ± 2,59) que os homens (13,33 ± 3,16) e também apresentaram o maior ICD total (P< 0,05). CONCLUSÃO: Os resultados obtidos neste grupo de trabalhadores brasileiros com síndrome do impacto do ombro identificam os mais comuns descritores utilizados para dor no ombro. Além disso, este estudo mostra que as mulheres estão mais propensas a relatarem incapacidade física e dor quando comparadas aos homens. Os questionários DASH e McGill de dor são ferramentas importantes e úteis na avaliação clínica da síndrome do impacto do ombro.


Subject(s)
Humans , Male , Female , Pain Measurement , Rotator Cuff , Shoulder Pain
4.
Braz. j. phys. ther. (Impr.) ; 10(2): 193-198, 2006. ilus, tab, graf
Article in Portuguese | LILACS | ID: lil-433929

ABSTRACT

CONTEXTUALIZAÇÃO: O instrumento mais utilizado pelos terapeutas para mensuração da amplitude de movimento (ADM) articular é o goniômetro universal. No entanto, há carência de estudos que analisem a confiabilidade das medidas da ADM do joelho realizadas no dinamômetro isocinético. OBJETIVO: O objetivo deste estudo foi analisar a correlação entre as medidas de ADM na articulação do joelho, realizadas com o goniômetro universal e no dinamômetro isocinético. MÉTODO: Foram avaliados 38 voluntários saudáveis (27 mulheres, 11 homens), com idade de 36 ± 11 anos, com limitação mínima de 20° na ADM de extensão do joelho. No membro dominante de cada sujeito foram realizadas três mensurações da ADM do joelho com o goniômetro e três mensurações no dinamômetro. RESULTADOS: Os resultados deste estudo mostraram que há alto grau de correlação entre as medidas da ADM do joelho obtidas com o goniômetro universal e no dinamômetro isocinético (Coeficiente de Correlação de Pearson = 0,90). CONCLUSÃO: Com os procedimentos realizados, tanto o goniômetro universal como o dinamômetro isocinético podem ser utilizados para avaliação da ADM do joelho, pois ambos apresentam mensurações confiáveis.


Subject(s)
Humans , Male , Female , Adult , Exercise Movement Techniques , Knee Joint , Physical Therapy Modalities , Rehabilitation/instrumentation
5.
Braz. j. phys. ther. (Impr.) ; 9(3): 265-271, set.-dez. 2005.
Article in Portuguese | LILACS | ID: lil-432247

ABSTRACT

As afeccoes do manguito rotador limitam o movimento humano e a avaliacao apropriada de suas estruturas e importante para o diagnostico e a reabilitacao dos individuos. No entanto, sao escassos os estudos morfometricos que fornecem detalhes sobre a localizacao topografica dessas estruturas. Objetivo: o presente estudo identificou a localizacao anatomica do tendao subescapular, um componente anterior do manguito rotador, em 3 posicoes usualmente utilizadas durante a palpacao para a avaliacao clinica: neutra, com o membro superior aduzido ao lado do torax (PN), antebraco fletido atras das costas (PAC) e antebraco fletido sobre o abdome (PAB). Metodo: foram dissecados 13 ombros de cadaveres adultos, de ambos os sexos. Nas posicoes adotadas foram mensuradas as distancias entre o tuberculo menor e o processo coracoide, assim como entre o tuberculo menor e o acromio. Resultados: as distencias do tuberculo menor ao processo coracoide nas posicoes PN, PAc, e PAB foram: 2,29 +-0,62 cm, 1,71+-0,52 cm, 1,27+-0,23 cm, respectivamente, com diferenca nas distancias da PN em relacao a PAC (p=0,01) e PAB (p=0,0001). As distancias do tuberculo menor ao acromio nas posicoes PN, PAC e PAB foram: 3,95+-0,59 cm, 4,96+-0,27 cm, e 4,04+-0,50 cm, respectivamente, com diferenca entre PN e PAC (p=0,0001) e entre PAC e PAB (p=0,0002). Foi identificada fusao do tendao do subescapular co o do supra-espinal e com a capsula articular. Algumas fibras tendinosas do musculo subescapular alcancam o ligamento transverso do umero. Conclusoes: Os resultados deste estudo mostram que a maior exposicao do tendao do subescapular ocorre na posicao neutra


Subject(s)
Anatomy , Rotator Cuff , Shoulder
6.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 8(1): 105-16, jan 1998. ilus, tab
Article in Portuguese | LILACS | ID: lil-234321

ABSTRACT

Neste artigo apresentam-se as arritmias mais encontradas na criança e no adolescente. Enfoca-se sob a óptica do cardiologista pediátrico, enfatizando-se o diagnóstico da arritmia e a conduta terapêutica.


Subject(s)
Humans , Male , Female , Child , Infant, Newborn , Arrhythmias, Cardiac/pathology , Heart Block/therapy , Tachycardia, Ventricular , Pediatrics
SELECTION OF CITATIONS
SEARCH DETAIL